Certifications

Aegex’s industrial mobile devices are designed to meet the highest international safety standards. They are tested and certified by UL, ATEX, IECEx and CSA as Intrinsically Safe for Division 1 and Zone 1 hazardous areas. To obtain all of these certifications in a single design requires our patent-pending technologies and testing.

Above all, Aegex is committed to safety. Even though our products have already been proven and certified as safe, we maintain a commitment to continual improvement. To achieve this, we conduct a range of environmental and electrical tests to determine if product safety can be improved. The learnings from these efforts can be applied to new products on our development roadmap. Additionally, we continue to seek partners with components or technologies that can work with us to further empower workforces in hazardous areas.

Unlike other intrinsically safe devices that encapsulate possible explosions inside the device, Aegex products prevent any spark from occurring in the first place, thus they are intrinsically safe at the board level. This method ensures an additional level of safety and peace of mind for our customers.

The Aegex10 IS Tablet is certified under the following certifications:

  • UL913 5th edition: C I, II, III Div 1 Gr A-G T4, Tamb= -10°C…+50°C; CI Zo Gr IIC T4 IP65, Tamb= -10°C…+50°C
  • CSA 22.2 part 157
  • IECEx 60079: Ex ib IIC T6 Gb, Ex ib IIIC T85°C Db IP6X, Tamb= -10°C…+50°C
  • ATEX: II 2G Ex ib IIC T6 Gb, II 2D Ex ib IIIC T85°C Db IP6X, Tamb= -10°C…+50°C
certimap

Read more about CE Conformity Standards.

Read More

Read more about IS related standards.

Read More

Details about Aegex’s intrinsic safety certifications

CLASS:

Presence of Hazardous Material

Where flammable gases or vapors are present in the air in quantities sufficient to produce explosive or ignitable mixtures.
Where high concentrations of potentially combustible dusts are present
Where easily ignitable fibers or flyings are present

DIVISION:

Presence of Hazardous Material

Where ignitable concentrations of flammable gases, vapors, or liquids can exist all of the time or some of the time under normal operating conditions.

GROUP:

Presence of Hazardous Material

Acetylene
Hydrogen, fuel and combustible process gases containing more than 30% hydrogen by volume or gases of equivalent hazard such as butadiene, ethylene, oxide, propylene oxide and arolein.
Carbon monoxide, ether, hydrogen sulfide, morphline, cyclopropane, ethyl and ethylene or gases of equivalent hazard.
Gasoline, acetone, ammonia, benzene, butane, cyclopropane, ethanol, hexane, methanol, methan, vinyl chloride, natural gas, naphtha, propane or gases equivalent hazard.
Combustible Metal Dusts
Combustible Carbonaceous Dusts
Other Combustible Dusts

ZONE:

Presence of Hazardous Material

Where ignitable concentrations of flammable gases, vapors, or liquids are likely to exist under normal operating conditions.